Technical assistance is available for our monitored customers when you need it. Please call PVS before making any changes to your system & make sure your system is on test with central station.

QUICK RESET TIPS 

Radionics systems (4112, 6112):

THIS THIS QUICK REFERENCE GUIDE DOES NOT TAKE THE PLACE OF THE MANUFACTURES OWNER'S MANUAL. PLEASE REFER TO IT FOR FURTHER INSTRUCTION. QUICK REFERENCE GUIDE FOR YOUR SYSTEM:

COMMAND 1: "ARMS EVERYTHING" Including motion detectors, Delay time in entry/exit doors.

COMMAND 2: "PERIMETER INSTANT" Arms perimeter with no delay time on doors. No motion detectors

COMMAND 3: "PERIMETER DELAY" Arms perimeter with delay time on doors. No motion detectors.

COMMAND 4: "RESETS" Resets flashing red zone light after alarm has gone off

COMMAND 6: "BEEP" Makes doors beep.

COMMAND 7: "FIRE" Fire alert

COMMAND 8: "PARTIAL PERIMETER" automatically bypasses open zone(s). Arms perimeter with delay time on doors. No motion detectors.

COMMAND 9: "POLICE" Police alert

If zone is open: Push command 1, tone will be heard, press command and enter.

A Command 44 Local Test
B Command 47 Power Reset

PLEASE NOTE THIS GUIDE DOES NOT TAKE THE PLACE OF THE MANUFACTURES OWNERS MANUAL. PLEASE REFER TO THE MANUAL FOR MORE DETAILED INFORMATION or call PVS if you need a hard copy.


Bosch System Panels: 2112 and 2212
Keypads: D202, D220, D222, D223:

Arm: Press [9] to Arm All; Press [0] to Partial Arm (pressing the button twice enables the system for INSTANT MODE)

EX: 00 will arm perimeter and all doors/windows will have NO DELAY (this is typically how you arm this system at night).

Disarm: Enter Code (If you are still in exit time, just press [CLEAR] to disarm.)

Check Faulted Zones: Faulted zones display automatically when faulted.

Bypass Zone(s): Press [Zone #] + [*].

Smoke Reset: After silencing siren by entering code, press [3] + code to reset smokes.
* If smoke has not cleared the alarm may resound. Clear the detector of smoke and repeat the sequence to reset.

Chime Mode On/Off: Press [7], keypad will display current setting.
To Change, enter code + [1] to turn off, [2] to turn on short beep, [3] to beep until CLEAR key is pressed, or [4] to beep until point closes.

Code Change: It is recommended that you contact PVS and make changes with our direction.
Enter [5], + [Old Code] + [New Code] same # of digits as old code, + [New Code] again.

GE Concord Quick Reference Guide:

Arming Buttons: (Press Once)
Stay:Arms the perimeter (no motions)
Away:Arms the entire System (including motions)
Disarm: Press disarm followed by your code to turn the system off
No Delay: After pressing AWAY or STAY, press the 4 button to arm the system with no delay

Changing Your Code:

Press 9 + your code + Scroll down to User Codes and press #. Scroll down to System Master Code and press #. Enter new 4 digit code and press #.

Panic Buttons:

Press & hold as shows below to activate panic alarms (Note: Immediate Dispatch)

Hold RED FLAME button for FIRE

Hold GREEN CROSS button for MEDICAL

Hold BLUE SHIELD button for POLICE

Door Chime:

Simply press 7 + 1 to turn door chime on and off.

Resetting System & Clearing Troubles:

If you have any “trouble” type messages always try pressing * to clear the system

If the system is beeping and you are unsure why try pressing * to clear the system

If you have a fire alarm you must arm and disarm the system to reset your system